The abbreviation DST stands for Diaskintest. This test is a specific method for diagnosing tuberculosis. Until recently, in order to identify the disease, patients were administered a drug containing waste products of Koch bacilli. This procedure is called the Mantoux test. Every year there were more and more complaints about the latter. This is due to the fact that a large number of patients have false results. Diaskintest is a modern analogue of the Mantoux test, characterized by a high degree of reliability.
What is DST?
To prevent the development of severe forms of tuberculosis and the timely development of pathology, the doctor needs to assess the body’s response to the vital activity of Koch’s bacilli, which are the causative agents of the dangerous disease. Based on the patient’s immune response, the specialist can conclude whether the person is infected or not.
It is important to understand that DST is a vaccination that has nothing to do with preventative ones. This is a modern drug, used in practice since 2015. It is an analogue of the drug “Tuberculin”, used for the Mantoux test. You need to know that DST is a method that has the highest degree of reliability. If a positive reaction is detected, the patient is indicated for hospitalization in a hospital, where he will undergo a course of anti-tuberculosis chemotherapy.
Di-test characteristics specifics
Diaskintest (DST) is a modern method for detecting tuberculosis, the principle of action is similar to the Mantoux reaction known to everyone since childhood.
This is not even a vaccination, but a test sample, a request from the body for the presence of pathogenic bacteria, causative agents of an unpleasant disease.
DST does not protect the body from the disease, but only detects its presence.
A protein drug (antigen) is injected under a person's skin to test the body's immune response. A positive diagnostic result suggests that the organism has already encountered such bacteria as the causative agents of the disease. It turns out that the infection has already penetrated some time ago, and the patient does not even suspect it.
Diagnostics using the drug Diaskintest has a higher accuracy of results when compared with checking the Mantoux test. This occurs due to the special composition of proteins that are sensitive to the pathogen and have anti-allergenic properties. Thus, the likelihood of a false-positive DST reaction is noticeably reduced.
Compound
Every parent should know that the DST vaccination is a test that does not contain waste products of Koch bacilli. It contains only synthetic antigens.
The allergen is a protein with two surface foreign agents, which the body perceives as tuberculosis pathogens. In addition to the active ingredients, the drug contains excipients:
- phenol (preservative);
- polysorbate (stabilizer);
- sodium and potassium phosphate;
- saline solution
The protein with antigens is more specific than the waste products of Koch's bacillus. In other words, the probability of a negative reaction occurring is highest in the absence of disease.
Some parents are concerned about the fact that DST is a test that introduces phenol into the child’s body. According to clinical studies, this substance is administered in a minimal dose. It is not capable of having a negative effect on the body of even a one-year-old child. In addition, the drug used to perform the Mantoux test also contains phenol.
Decoding the result: norm and deviations
The result should be assessed by a medical professional by measuring the diameter of the mark after the injection with a transparent flexible ruler with millimeter divisions.
The appearance of the papule is also examined (the presence of redness, swelling, and other abnormal phenomena).
There are the following reactions for the DST test:
- Negative. There is no trace, swelling. Redness or induration up to 1 mm in size is allowed. This result is considered normal and indicates the absence of infection. For children, this means that after a month they can be immunized against tuberculosis with BCG.
- Positive. In the injection zone there is a mark with a diameter of 5 to 14 mm. There may also be redness, swelling, and thickening. Indicates the presence of Koch's bacillus in the body. It is an indication for referral to a tuberculosis clinic and initiation of anti-tuberculosis therapy. A positive reaction, in turn, is divided into mild (papule with a diameter of 5 mm), moderate (trace size from 5 to 9 mm) and pronounced (formation 10-14 mm).
- Doubtful. The mark after injection measures up to 5 mm. There may be no papules, but then there is hyperemia. There is slight redness and swelling. If such a result is obtained, a person needs additional examination.
- Hyperergic. The diameter of the papule exceeds 15 mm. Sometimes vesiculo-necrotic changes are present (abscess, severe inflammation).
The stronger the response, the more active the infection is in the body.
Dates
There are certain standards approved by the Ministry of Health. They strictly regulate the frequency of DST vaccination.
The deadlines are as follows:
- Diaskintest is indicated for children and adolescents whose age is in the range of 8-17 years. The test is carried out once a year as part of a mass survey of the population to detect tuberculosis.
- If the child has not been vaccinated with BCG, Diaskintest is indicated once every 6 months.
- Adults should know that DST is a test that applies to them as well. Men and women are also recommended to administer the drug every year for preventive purposes.
- For children from 1 to 8 years of age, the test is performed only if a positive Mantoux reaction is detected.
In all other cases, the timing of placement is determined by a doctor (pediatrician or therapist). Diaskintest can be repeated no earlier than 2 months after receiving a negative result. If the reaction is positive, the timing of the placement can be any. But in this case, the duration of the time intervals should also be determined by the doctor, taking into account the individual health characteristics of the patient. In addition, DST is not carried out earlier than 30 days after vaccination and acute infectious pathologies.
DST-14 Scanner-tester Automotive diagnostic scanner-tester DST-14
Scanner-tester DST-14
Price:
DST-14-Kf: 36,500 rub. DST-14/NK1: 43,500 rub.
Applicability table
The DST-14 hardware scanner is the most modern model of scanners in the DST line from the famous. It is intended for diagnosing electronic engine control systems and other systems (transmission, ABS, etc.) of domestic cars (VAZ, GAZ, IZH, ZAZ, UAZ, GM-AVTOVAZ, PAZ, MAZ, SeAZ, KAMAZ (including Chevy Niva , Chevy Viva, Lada Granta) and imported (VAG group (Audi, VW, Skoda, Seat), Daewoo/Chevrolet, Kia, Opel, Renault, Peugeot, Fiat, Citroen, Hyundai, Ford, BAW, Great Wall, Chery , Mazda, Toyota/Lexus, Nissan, Foton, Ssang Yong, Hafei, as well as vehicles that support diagnostics according to OBD and CAN standards).
Description
The cartridge-less hardware device DST-14 is a scanner-tester with expanded memory and a convenient way to update software via the USB interface. It replaced the well-proven DST-12 scanner and is an improved, latest version of scanners in this line. It consists of a scanner unit, diagnostic and interface cables.
The scanner unit is made of impact-resistant plastic, which is highly resistant to aggressive liquids (gasoline, oils, etc.) and temperature changes. On the scanner body there is a control panel and a matrix liquid crystal display (128 x 64 pixels), which allows you to work in both text and graphic modes. The scanner adapter supports data exchange standards via K-Line, L-Line (in accordance with ISO9141 and ISO14230 standards -1), RS-232 and for power connection. Other supported diagnostic interfaces: J1850 PWM/VPW and CAN: ISO11898 (High speed), ISO11519 (Fault tolerant), J2411 (Single wire). Overall dimensions - 205x100x37 mm, weight 350 grams.
DST-14 is a scanner-tester with extended memory and a convenient way to update software via USB interface. Free software update for one year from the date of sale! Today it includes all diagnosable units, as in DST-12, as well as new diagnostics for Nissan cars.
The memory capacity of DST-14 is many times increased compared to the memory of the previous model DST-12 and amounts to 500 megabytes (the NPP NTS software developed to date takes no more than 30 MB). The list of diagnosed blocks depends on the software version and can expand as new blocks are added. The latest list of diagnosed car brands and units can be found on the manufacturer’s website www.nppnts.ru. The manufacturer is constantly developing and adding new diagnostic modules. To update the software, the user will need: scanner tester DST-14, a standard USB cable and power supply (from the main delivery package), a computer with a USB 2.0 port, an Internet connection and basic skills in working with a computer, programs and files.
Attention! Free software update for a year from the date of sale (and not until the end of the calendar year, as for DST-12).
All data is displayed in Russian in digital form. The device allows you to save test results in its non-volatile memory for subsequent analysis. DST-14 can operate from a supply voltage of +12V and +24V, which allows you to diagnose both cars and trucks. To exchange data with a computer, you need specialized DstLink software, which allows you to read data from DST-14 for more thorough processing of the obtained engine operating parameters and maintaining databases.
DST-14 is an indicator-type diagnostic device; in terms of metrological properties, it belongs to products that are not measuring instruments and do not have precision characteristics, in accordance with GOST 25176, and does not require verification.
Comparative characteristics of DST-14 and DST-12 are given in the table:
Comparison of DST-14 and DST-12 | |||
Characteristics | Diagnostic scanner tester DST-14 | Diagnostic scanner tester DST-12 | |
Software | Software modules (hereinafter referred to as modules) | Firmware programs | |
Memory | At least 500 MB. All NPP NTS software developed to date takes no more than 30 MB. | 16 megabytes, which allows you to simultaneously store up to 16 programs - firmware (out of 28 available today) in the DST-12. | |
Nutrition | +12V and +24V for diagnostics of cars and trucks | ||
Supported diagnostic interfaces | K-Line, L-Line, J1850 PWM/VPW, CAN: ISO11898 (High speed), ISO11519 (Fault tolerant), J2411 (Single wire). | ||
Software Update | To update software via USB, use a standard USB cable. | To update the software via the RS-232 interface, use the DST-12-PK kit. | |
To operate DST-14, an activation key is required. During production, an activation key is written into DST-14, which allows you to work with software modules that already exist and were released within 1 year and 3 * months from the date of production of DST-14. Modules released after this period require a new activation key to operate. The new key allows you to work with modules that existed before the key was issued and were released within 1 year from the date the key was issued. Software modules already authorized by the activation key will work indefinitely. A new activation key can be purchased from dealers or NTS NPP, and modules can be downloaded from the NTS NPP website for free. * additional 3 months - approximate time from issue to sale. | The DST-12 tester software can be updated at dealers or independently using the current registration code (the code is valid for updating tester firmware released before the end of the calendar year). To update firmware that will be released in the next calendar year, you will need to purchase a new registration code. | ||
Cables and accessories | Diagnostic cable SO4-D12-DIAG, Cable adapter OBD II AM4-D43-OBD II, Cable adapter GAZ AM4-D22-GAZ, Cable SO4-D21-VAZ, Cable SO4-D41-GAZ ABS, Cable adapter VAG- 4 AM4-D52-VAG, Adapter cable VAZ/GM-12 AM4-D32-VAZ, Power cable SO4-D32-VAZ AKK, Steyr adapter cable AM4-D62-Steyr Supplied separately or main cables are included in the delivery option PC (full set). | ||
Included in the main package: USB 2.0 AM/miniB 5P cable Power supply 12V 1A | Supplied separately: Set DST-12-PK |
Functionality
n/n | Software modules | Current version January 2012 | Supported blocks |
1 | VAZ new | v_0.1.1.1 | VAZ Bosch M1.5.4 R83, M1.5.4+ R83 Bosch M1.5.4N E2 Bosch MP 7.0 E2 Bosch MP 7.0 E3 Bosch M7.9.7 E2 Bosch M7.9.7 E3 Bosch M7.9.7 E4 Bosch ME17.9.7 VS 5.1 R83 VS 5.1 E2 January-4 January-5.1.x R83 January-5.1 E2 January-7.2 GM ISFI-2S GM EFI-4, ITMS-6F M73 E3 M74K M74 M75 M74 CAN Climate control SAUO/SAUKU Immobilizer APS-6 SNPB VAZ-2110 SNPB VAZ-1118 SNPB VAZ-2170 EURU VAZ-1118 EURU VAZ-2170 EURU MANDO Co BOSCH ABS 8 Electrical package KALINA Electrical package KALINA-LUX Electrical package PRIORA BUSO SNPB TAKATA SEAZ/KAMAZ OKA Bosch M154 OKA E3 IZH MIKAS 7.6 ZAZ MIKAS 10.3 MIKAS 11.3 |
2 | GAZ_UAZ | v_1.1.1.0 | GAS MIKAS-5.47 (M1.5.4) MIKAS-7.1 MIKAS-11 E2 MIKAS-11ET E3 MIKAS-11MT E3 MIKAS-11CR E3 VS 5.6 VS 8 SOATE Avtron SOATE 31.3763 VDO Steyr MKD-105 LDV Maxus Valdai GAZ 3307 Bosch ME17.9.7 Chrysler 2.4L DOHC Volga Siber engine 2.4L UAZ MIKAS-7.2 MIKAS-11 E2 MIKAS-10.3 (11.3) Bosch ME17.9.7 (petrol) EDC16C39 (UAZ Patriot diesel) VS 9.2 (diesel) GROOVE EDC7UC31 Mikas 11V8 ZIL EDC7UC31 MAZ EDC7UC31 E3 Elara 50.3763-30 Other controllers: GAZ Bosch ABS 5.3 Bosch ABS 8 LDV Maxus SRS LDV Maxus Security Alarm LDV Maxus Immobilizer LDV Maxus ABS Volga Siber MIC Volga Siber AT Volga Siber Audio Volga Siber Airbag Volga Siber Immobilizator Volga Siber ABS Volga Siber BCM UAZ Bosch |
3 | VAG | v_5.1.1.0 | Volkswagen (KW1281, KW2000, KW6000) Audi (KW1281, KW2000, KW6000) Skoda (KW1281, KW2000, KW6000) Seat (KW1281, KW2000, KW6000) |
4 | KIA | v_6.1.1.0 | ECM controllers: Spectra 1.6L Shuma II 1.6.L Cerato 1.6/2.0L: EOBD(+CVVT) 2004-2006 EOBD(-CVVT) 2004-2006 GEN (+CVVT) 2004-2006 GEN (-CVVT) 2004-2006 DOHC EOBD 2004- 2006 DOHC GEN 2004-2006 SOHC LEAD 2004-2006 Picanto 1.0/1.1L: SOHC EOBD 2004-2007 SOHC GEN 2004-2007 SOHC LEAD 2004-2007 Cerato 2007-09 1.6L Unlead EOBD 1.6L Unlead GEN 1.6L Lead AL Other controllers: |
5 | GM_AVTOVAZ | v_7.1.1.0 | ECM controllers: GM-AVTOVAZ Z18XE_NIVA Z18XE_VIVA Bosch MP7.0 -Euro2 Bosch M7.9.7-Euro2 Bosch M7.9.7-Euro2 AC Bosch M7.9.7-Euro3 AC Bosch M7.9.7-Euro4 AC Other controllers: GM-AVTOVAZ BOSCH ABS 5.3 NIVA BOSCH ABS/ASR 5.3 VIVA BOSCH ABS 9.0 SNPB VAZ-2123 SNPB TRW APS-6 EP NORM |
6 | OBD-II | v_9.1.1.0 | OBD-II/EOBD (ISO 14230, SAE J1941, CAN 2A/2B, SAE J1850 VPW/PWM) |
7 | OPEL new | v_10.1.2.0 | ECM controllers: Simtec 56.5 Astra-F 1996-1998 Calibra 1996-1997 Omega-B 1996-2001 Vectra-B 1996-2003 Simtec 7.0 Astra-G 1998-2003 Vectra-B 1998-2003 Zafira 1999-2003 Multec U Astra-F 1993-2001 Astra-G 1998-2001 Simtec 7.1 Astra-G 2001-2003 Corsa-C 2001-2003 Omega-B 2000-2003 Vectra-B 2000-2003 Zafira 2001-2003 Multec F Astra-F 1996-2001 Corsa-B 1996-2002 Tigra 1996-2000 Vectra-B 1996-2001 Multec H Astra-G 1998-2003 Vectra-B 1998-2000 Zafira 1999-2001 M 1.5.4 Astra-F 1995-2000 Frontera 1995-1998 Omega-B 1994-1999 Vectra-B 1996-2000 Simtec 56 Astra-F 1993-1996 Calibra 1994-1996 Omega-B 1994-1998 Vectra-B 1996-1998 Astra-G Z16SE (2001-2006) Antara/Captiva Z24XE (2008) Other controllers: Body: |
8 | PEUGEOT | v_11.1.1.0 | Peugeot: 206 (Engine, Transmission) 306 (Engine) 307 (Engine, Transmission, SRS, ABS) 405 (Engine) 406 (Engine) 607 (Engine) 806 (Engine) 807 (Engine) Expert (Engine) Partner (Engine) |
9 | HYUNDAI | v_12.1.1.0 | ECM controllers: ACCENT 2003-05 (Lead All, Unlead GEN, Unlead EOBD, Unlead 03MY, Unlead 04MY, CRDi) ACCENT 2003-08 (TagAZ) GETZ 2003-05 (Unlead EOBD, Unlead Gen, Lead All) GETZ 06- (Lead All, Unlead) ELANTRA 2004-06 (1.6L Lead All, 1.6L Un.GEN, 1.6L Un.EOBD, 1.8/2.0L Lead, 1.8/2.0L -CVVT, 1.8/2.0L +CVVT, 1.8/2.0L EOBD, 2.0L +CVVT OBD, Diesel VGT) ELANTRA 07- (1.6L Unlead Gen, 1.6L Unlead EOBD,1.6L Unlead OBDII,1.6L Lead All) TERRACAN 2.9LD (2.9L CRDi) SANTA FE (Diesel VGT, Diesel WGT, 2.4L Unlead EOBD, 2.0L Unlead EOBD, 2.0/2.4L Ulead GEN, 2.0/2.4L Ulead OBDII, 2.0/2.4L Lead All) SONATA 2.0/2.4L (Un. -ETS GEN, Un. -ETS EOBD, Lead -ETS All, Un. +ETS GEN, Un. +ETS EOBD, Lead +ETS All) NF 2.0/2.4L (Un. -ETS GEN, Un. -ETS EOBD, Lead -ETS All, Un. +ETS GEN, Un. +ETS EOBD, Lead +ETS All) SANTAFE 2.7L (Zr O2S(OBD-II), Zr O2S(EOBD), Zr O2S(GEn), Ti O2S(OBD-II), Ti O2S(EOBD), Ti O2S(GEn),Lead All) Other controllers: Transmission: SANTA FE Automatic Transaxle |
10 | RENAULT | v_13.1.1.0 | ECM controllers: Scenic Engine Clio Engine Clio II Clio II 2001 Clio II Phase 2 Symbol Megane Thalia Megane II Sagem S3000 Logan 2004MY (Sirius32-EMS3132) Logan 2008MY (Sirius32-EMS3132) Dacia (Renault) Logan MCV 1.6L 16V (Sirius32-EMS3132) Dacia (Renault) Logan MCV 1.5L (diesel) (Delphi DCM 1.2) Laguna II Other controllers: |
11 | FORD | v_14.1.1.0 | FOCUS/FOCUS II: Engine ABS Comfort System Information System Body Control System Under Car Door Control Audio System Safety System Light Control Instrument Cluster Automatic Transaxle |
12 | DAEWOO - CHEVROLET | v_15.1.1.0 | DAEWOO: Includes blocks: Espero Prince Cielo Nexia Leman Racer Lanos Nubira Nubira II Leganza Magnus Rezzo Nexia UZ (+Euro3) Matiz (Eng(0.8/1.0, M200), Transmission, ABS) Kalos |
13 | FIAT | v_17.1.1.0 | ECM controllers: Albea (1.2L(1997-2004), 1.5L(2000-2004), 1.6L(1997-2004), 1.9LD(2000-2004), 1.9LTD(2001-2004), 1.4L 8V IAW-5SF) Palio (1.2L(1997-2004), 1.5L(2000-2004), 1.6L(1997-2004), 1.9LD(2000-2004), 1.9LTD(2001-2004)) Doblo (1.2L(2000-2004) , 1.6L(2003-2004), 1.3LTD, 1.9LD(2000-2004), 1.9LTD(2000-2004)) Siena (1.2L(1997-2004), 1.5L(2000-2004), 1.6L(1997 -2004), 1.9LD(2000-2004), 1.9LTD(2001-2004)) |
14 | CITROEN | v_18.1.1.0 | ECM controllers: C3 Engine 1.4L KFV(Sagem S2000PM1) C4 Engine 1.6L 16V MPI CAT NFU C4 Engine 1.6L 16V T-Diesel 9HX/9HY/9HZ C4 Engine 2.0L 16V MPI CAT RFJ C4 Engine 2.0L 16V MPI CAT RFN C4 Engine 2.0L T-Diesel RHL C4 Engine 2.0L T-Diesel RHR C5 Engine 1.6L 16V MPI CAT 5FZ C5 Engine 1.8L 16V MPI CAT 6FZ C5 Engine 2.0L 16V MPI CAT RFN C5 Engine 2.0L 16V MPDI CAT RLZ C5 Engine 2.0L T- Diesel RHY C5 Engine 2.0L T-Diesel RHZ |
15 | CHERY | v_19.1.1.0 | ECM controllers: Tiggo (T11) Delphi System Sweet (QQ, S11) QQ3 MT MM 372/472 System QQ6, A1 & V2 series MT MM 472 System A3 Sedan/Hatchback A520/A516 (Fora) A15 (Amulet) QQ6 UAES QQ3 Engine MT Siemens 372 System QQ3 Engine MT Troitec System |
16 | SUZUKI | v_20.1.1.0 | ECM controllers: Grand Vitara Engine 2.0L L4J20 Grand Vitara Engine 2.0L L4J20 JB Series |
17 | BAW/FOTON | v_21.1.1.0 | ECM: BAW — Fenix 1044 (CA4DC2-10E3) — Fenix 1065 (CA4DC2-12E3) |
18 | TOYOTA_LEXUS | v_22.1.1.0 | ECM controllers: Engine General |
19 | GREAT WALL | v_23.1.1.0 | GreatWall/BYD/Lifan: GW413EF Union EOBD Union ECU System of second generation Delphi ECU System Delphi EOBD ECU Spaceflight MIT ECU System |
20 | MAZDA | v_27.1.1.0 | Includes units: ECM controllers: Mazda 2/Mazda 3/Mazda 6 |
21 | SSANG YONG | v_29.1.1.0 | Action Diesel DSL D27DT(C2I) Euro 3 Rexton Diesel DSL D27DT(C3I) Euro 4 |
22 | NISSAN | v_33.1.1.0 | Includes units: ECM controllers: Nissan Engine K-Line ECU10 Nissan Engine K-Line ECU12 Nissan Engine CAN |
23 | HAFEI | v_34.1.1.0 | Includes units: ECM controllers: Hafei Lobo_Brio Engine 1.1 |
Scanner functions:
- Read system data;
- Display diagnostic trouble codes;
- Erase fault codes;
- Control the actuators of the vehicle;
- Record and save the values of variables and state flags in the tester’s memory;
- Display data in both text and graphical modes;
- Set a password; (Delete)
- The parameters obtained from the ECU during diagnostics and stored in the tester’s memory can be copied to a computer for further analysis. After importing into MS Excel or OpenOffice, the names and values of the parameters can be viewed in the form of a table or graph.
Equipment
Delivery set of DST-14-Kf:
- Scanner DST-14
- Passport
- Bag for transportation and storage
- Documentation on CD
- USB 2.0 AM/miniB 5P cable
- Power supply 12V 1A
Delivery set DST-14/NK1 (optimal set):
- Scanner DST-14
- Passport
- Bag for transportation and storage
- Documentation on CD
- USB 2.0 AM/miniB 5P cable
- Power supply 12V 1A
- Diagnostic cable SO4-D12-DIAG (universal extension cable for all cars)
- OBD II adapter cable AMD4-D43-OBDII (for cars with OBDII 12/24V diagnostic block)
- Adapter cable GAZ AM4-D22-GAZ (for GAZ, UAZ cars)
- Adapter cable VAG-4 AM4-D52-VAG (for VAG group cars: Audi, VW, Skoda, Seat, manufactured before 1994)
- Cable SO4-D21-VAZ (for VAZ, IZH and DAEWOO cars with a 12-pin diagnostic connector (GM))
- Power cable SO4-D32-VAZ ACC (for use together with cable SO4-D21-VAZ and SO4-D41-GAZ ABS)
Additionally you can purchase:
- Adapter cable VAZ/GM-12 for VAZ cars powered by the diagnostic block (AM4-D32-VAZ).
- Steyr adapter cable for connection to vehicles with VDO Steyr (GAZ-560) ECU (AM4-D62-Steyr).
- Cable for connecting to the ABS of GAZ cars (СО4-Д41-ГAZ АБС).
- DEUTSCH9 adapter cable for trucks with J1939 9pin connector (KAMAZ – Cummins) (AMD4-D45-DEUTSCH9).
You can order an application for the purchase of equipment by phone. +7
- Star Diagnosis Compact4 SDconnect,
- Star Diagnosis D3,
- Star Diagnosis Carhelp (com+usb),
- BMW GT1,
- BMW GT1 Carhelp,
- BMW OPS,
- BMW OPPS,
- BMW ICOM,
- BMW ISIS,
- BMW ISID+ISSS+ISIS,
- VAS 5051B,
- VAS 5052,
- VAS 5052A,
- VAS 5054A,
- Porsche Piwis Tester,
- Porsche Piwis Tester II,
- Ford IDS VCM,
- T4 Land Rover Mobile Plus,
- Volvo Vida Dice,
- GM MDI,
- Tech 2,
- Toyota Tis Techstream,
- Honda GNA-600,
- Nissan Consult 3,
- MUT 3
- Subaru Select Monitor III,
- Intelligent Tester II
- Suzuki SDT,
- Renault CAN Clip,
- PSA XS Evolution,
- Lexia-3,
- StarScan
- Scan-100,
- Hi-Scan Pro,
- G-Scan
- Ferrari Maserati SD4,
- DURAMETRIC
- TwinB BMW Gt1 PRO+MB Star C4,
- TWINB II MINI OPS + MB Star c4,
- TWINB IS GT1+MINI OPS,
- BMW Mini OPS,
- BMW inpa 5.0,
- Volvo ALL SCANNER ,
- MB C4 ,
- MB CarSoft 7.4
- MAN CATs II,
- MAN T200,
- MAN Cardaq,
- Volvo Vcads (non-original),
- Volvo VCADs Interface 88890020,
- DAF VCI-560,
- Scania VCI 1,
- Scania VCI 2
- Iveco EASY,
- Renault Diag NG3,
- Nexiq USB Link,
- TruckHelp,
- MB Star Diagnosis,
- Isuzu IDSS,
- Tech 2 Isuzu,
- AVTOAS-CARGO,
- Mscan EDC-24 (KAMAZ, etc.),
- DK-5,
- DK 2.03 (MAZ, etc.),
- AKM LITE,
- ASKAN-10.230,
- ZF Testman,
- Knorr-Bremse,
- Wabco for tractors,
- Wabco for buses,
- Wabco for trailers,
- Wabco tractors+trailers,
- Wabco DI-2,
- Hino,
- Nissan UD,
- Renault Diag NG10,
- DPA 5 Quad-CAN full kit,
- DPA 5 Dual-CAN base,
- DPA 5 Dual-CAN full kit,
- DPA 5 Quad-CAN base,
- NOREGON JPro Fleet,
- Noregon Jpro DLA+,
- Nexiq PRO-Link IQ
- Launch X-431 Master,
- Launch X-431,
- Launch X-431 GX3,
- Multiscan
- Ultrascan
- AXONE 4
- TEXA TXT,
- AXONE-Smart,
- OBD Log,
- G-Scan
- Carman scan VG+,
- Carman scan Lite,
- Carman scan WI,
- Carman Scan VCI
- Bars 4 Professional,
- Scanmatic,
- Scanmatic 2 USB,
- Autoas-scan,
- Askan,
- Avtoas-F16,
- ScanDoc
- SMS-diagnostics 2,
- VAG-Com-Hex-Can-Usb,
- Uniscan,
- DST-12,
- Bosch KTS-530/540/570,
- BMW Pasoft 1.40 Carhelp,
- Scantronic-2,
- Chip tuning,
- Autoboss-V30,
- Carman Scan AT,
- Bosch KTS-200,
- Bosch KTS-340,
- Genisys
- Nemisys,
- ETHOS Ru,
- SOLUS
- Carman Scan-I
- MaxiDas DS708 ,
- Magneti Marelli Smart ,
- Magneti Marelli Vision ,
- Magneti Marelli Logic ,
- JBT-CS538D ,
- JBT-CS538C,
- Toyota ALL SCANNER,
- DST-14,
- iScan II
- AXONE 4
- Texas Axone-3,
- AXONE-Smart,
- Texas Navigator TXT,
- Texas Axone 2000,
- Texas Tribox Mobile,
- OBD Log,
- Auto-Com
- Jaltest,
- Nexiq USB Link,
- G-Scan
- Bosch KTS Truck,
- XTOOL PS2 Truck,
- Cummins INLINE 5
- Launch X-431 Heavy Duty,
- JBT-CS638B,
- Abritus,
- FCAR-F3-D
,
,
What rules must be followed after testing?
The drug is administered subcutaneously. The setup algorithm is identical to the procedure for performing the Mantoux test.
In order for the test results to be reliable, several recommendations must be followed:
- Until the DST is deciphered by a doctor, do not take water procedures. In this case, it is allowed to wet the injection site, but it is desirable that skin contact with water be as short as possible and only when necessary.
- The injection site should not be scratched, rubbed, treated with topical preparations for faster healing, wrapped in a bandage or covered with a band-aid.
- It is recommended to avoid high-intensity physical activity until you visit your doctor again. Sweating can cause changes in the ongoing reaction.
In addition, it is not recommended to spend a long time in the sun or walk in severe frost.
Interpretation of results
The DST vaccination is deciphered by a therapist or pediatrician. At the same time, during the assessment, experts rely on certain criteria.
Result options:
- The reaction is negative. The doctor did not detect any changes at the injection site. This result indicates that there are no mycobacteria in active form in the body of the person being studied. Directly at the injection site, you can visualize the injection mark. If the algorithm is violated during staging, in some cases a hematoma forms. Parents are worried that the DST vaccine has turned blue. What it is? This condition indicates rupture of small blood vessels. It is not pathological and does not warrant immediate medical attention. The only difficulty is that a bruise at the injection site can distort the results, as if masking the redness. In such situations, repeated testing is indicated.
- The reaction is positive. The first sign of the presence of Koch bacilli in the body is an infiltrate at the site of drug administration. Moreover, the more pathogens, the larger the compaction. It can reach 15 mm in size. It is important to understand that a positive Diaskintest result indicates infection, and not the active course of the disease. Many people have Koch bacilli in their bodies, but they are in a dormant state. Their transition to the active phase can occur under the influence of various unfavorable factors. Indications for immediate therapy are: infiltrate more than 15 mm, inflamed lymph nodes, vesicular and crusty structures at the injection site.
The result may also be considered doubtful. For example, in the event of a bruise that may prevent the doctor from correctly interpreting the reaction.
How the test is carried out
Diaskintest does not require special preparation. But for the analysis, the child must be healthy and have no signs of allergies. Therefore, the pediatrician first examines the patient, measures temperature, pressure, and palpates the lymph nodes. Such measures are necessary to minimize the likelihood of adverse reactions.
People who are prone to allergies are advised to take an antihistamine on the day of the test. Also, on the eve and on the day of the procedure, highly allergenic foods should be excluded from the diet (for example, strawberries, chocolate, citrus fruits, pastries and cakes with dyes, juices with preservatives). This will help avoid the spread of infiltration and the appearance of skin rashes.
Diaskintest technology:
- The patient sits on a couch or chair.
- The forearm is treated with an antiseptic drug (alcohol).
- The nurse draws a test substance into a disposable syringe.
- A puncture is made in the middle third of the forearm and a dose of the product is injected intradermally.
- The injection site is wiped with alcohol.
Normally, a thickening (papule) should appear on the skin. Soon it disappears or transforms into a denser formation. After 72 hours, the reaction is assessed.
Reasons for false results
In isolated cases, DST is positive in the absence of a pathogen in the patient’s body. This may be due to the following conditions:
- The doctor ignored the existing contraindications for the patient.
- The injection site was infected.
- After administration of the drug, an allergic reaction to the protein occurred.
- The patient has autoimmune pathologies.
Adults are prohibited from drinking alcohol-containing drinks before taking the test and before assessing the reaction. Alcohol can significantly distort the results.
Contraindications
Like any other test, DST has a number of limitations. Main contraindications to the administration of the drug:
- Dermatological diseases accompanied by extensive rashes.
- Epilepsy.
- The presence of any pathologies in acute form.
- Increased body temperature.
- Individual intolerance to the components included in the drug.
The list of contraindications can be expanded by the attending physician based on medical history and examination.
Side effects
According to numerous reviews, the drug is well tolerated by most patients. Some people may experience a slight deterioration in their overall health. This appears as:
- Episodes of headache.
- Increased body temperature.
- General malaise.
- Allergic reaction (itching, shortness of breath, rashes, swelling of the nasopharynx).
An abscess or bruise may form at the injection site. Adults sometimes experience surges in blood pressure.
In most cases, side effects are short-term. As a rule, they go away on their own within a few days or even hours. If an allergic reaction occurs, doctors recommend taking an antihistamine, such as Zyrtec or Erius.
If an abscess occurs at the injection site, you should consult a doctor. This phenomenon indicates infection of the wound.